| Specifications |
|
| Connectors |
4 software selectable RS232/422/485 serial ports
(Cisco compatible RJ-45 pinout)
2 RJ-45 10/100Base-T primary Ethernet port
2 External USB-2 expansion connectors
2 TTL level digital I/O ports. 5V max @ 20mA. Also provides contacts for external water /smoke/ motion sensors
2 High-Voltage digital output ports (>5V to <= 30V@ 100 mA) |
| Power |
ACM5004-2-I
Requires external power source +9V to 30 VDC or 9V to 24 VAC
Also supplied with 110-240V AC external power adapter (for operations up to 50° C only)
Screw terminal block or barrel connector
Power Consumption less than 6W
ACM5004-2-I-SDC
36-72V DC to 12V DC external power converter
Also supplied with 110-240V AC external power adapter
|
| Dimensions |
4" x 3.5" x 1 1/8"
(10.2 x 8.8 x 2.8 cm)
|
| Environmental |
Humidity: 5% to 90%
Internal temperature sensor
ACM5004-2-I and ACM5004-2-I-SDC
Ambient operating temperature: -35° to 74° C (-31° to 165° F)
Non operating storage temp: -40° to 85° C (-40 to 185° F))
|
| Emissions |
FCC Part 15 Subpart B Class A Radiated Emissions 30MHz – 1000MHz
ICES-003 Issue 4 February 2004 Class A Radiated Emissions 30MHz – 1000MHz
AS/NZS CISPR 22: 2004 Class A Radiated Emissions 30MHz – 1000MHz
EN55022: 1998 + A1: 2000 + A2: 2003 Class A Radiated Emissions 30MHz – 1000MHz |
| Immunity |
EN55024: 1998 +A1: 2001 +A2: 2003
IEC61000-4-2: 1995 ESD 8kV Air Discharge (Direct), 4kV Contact Discharge (Direct/Indirect)
IEC61000-4-3: 1995 Radiated Immunity 3.0V/m, 1KHz AM Sine Wave at 80%
IEC61000-4-4: 1995 EFT/Burst 1.0kV Power Lines, 0.5kV I/O Lines
IEC61000-4-5: 1995 Surge Immunity 1.0kV Common Mode, 1.0 kV Differential Mode
IEC61000-4-6: 1996 Conducted Immunity 3.0 Vrms, 80% AM Modulated (1KHz)
IEC61000-4-11: 1994 Voltage Dips and Interrupts (>95%,0.5 periods), (30%,25 periods), (>95%,250 periods) z |
| Emissions |
Serial Port: 4 kV ESD protection on RS232 and RS422/485 transceivers
Ethernet Port: 1500 VAC isolation shielded with shield connected to chassis ground for signal integrity and ESD protection |
| Emissions |
CE
UL 1950
TUV
C-Tick
RoHS compliant
Security features to support NERC CIP standards
FIPS 140-2 Validated Module Certificate #1051 |
| CPU |
250Mhz Micrel KSZ8692 ARM9 System on Chip
|
| Memory |
32MB DDR RAM
16MB Embedded Flash
ACM500x-x-F:
Optional 2GB Internal USB Flash
|
| Operating System |
Linux with source code access
Custom development kit
|
|